Cell Voltage Monitor & Logger CellLog 8S
SELECT TYPE
LiPo
Lilo
LiFe
LiPo
Rename
New Name
LiPo-1200mAh
ALARM SETTING
Cells Voltag
Pack Voltage
Safety Timer
Alarm Trigger
LiPo
Select
Rename
Alarm
PACK ALARM VOLT
HV43.00V
LV1.000V
P42.00V
Pack Alarm Upper Limit
Pack Alarm Lower Limit
Pack Alarm Difference
CELLS ALARM VOLT
HV 4.22V
LV 3.00V
V 500mV
Cell Alarm Upper Limit
Cell Alarm Lower Limit
Cell Alarm Difference
Monitor Alarm Settings
The system can have 8 sets alarm settings, press <▲> for 3 seconds to enter SELECT TYPE menu.
The item with is the current setting.
<▲> or <▼> to select items and press < > button.
Defaulted TYPEs are: LiPo, Lilo, LiFe, User1--5
Operate the selected type settings
<▲> or <▼> to select the items, press < > to enter to the next step.
See details below.
Note: Press<▲> button to power on, it will shift to LiPo Type automatically.
Press <▼> button to power on, it will shift to Lilo Type automatically.
Press < > button to power on, it will shift to LiFe Type automatically.
Change Current Alarm Type: SelectSelect, Press < > then the item will be with , and the settings
come into effect.
Rename Alarm Type: SelectRename, press < > and the screen shows:
New Name Input Method: <▲> to select characters, hold it to trigger
continuously; <▼> to delete the current character; < > to confirm the
selected character; press < > for 2 times to confirm the amendment
and return; press < > for 3 seconds to cancel and return.
Alarm Parameters Setting: SelectAlarm, press < > and the screen shows:
<▲> or <▼> to select items, press < > enter to the next step
See details below.
1) Individual Cell Voltage Alarm Settings: SelectCells Voltage, press < > and the screen shows:
<▲> or <▼> to increase/decrease voltage value, press < > to shift
setting items. Press < > for 3 seconds to confirm amendment and
return.
HV : 1.31V4.90V LV: 1.30V4.89V V: 0.013.60V
2) Pack Alarm Voltage Setting: SelectPack Voltage, press < > and the screen shows:
<▲> or <▼> to increase/decrease voltage value, press < > to shift
setting items. Press < > for 3 seconds to confirm amendment and
return.
HV: 1.05V43.00V LV: 1.00V42.95V P: 0.0542.00V
< >